# Get-ProvServiceStatus
Gets the current status of the MachineCreation Service on the controller.
Syntax
Get-ProvServiceStatus [-AdminAddress <String>] [<CommonParameters>]
Detailed Description
Enables the status of the MachineCreation Service on the controller to be determined. The database connection to the service does not need to be configured before using this command.
Related Commands
Parameters
Name | Description | Required? | Pipeline Input | Default Value |
---|---|---|---|---|
AdminAddress | Specifies the address of a XenDesktop controller the PowerShell snap-in will connect to. You can provide this as a host name or an IP address. | false | false | Localhost. Once a value is provided by any cmdlet, this value becomes the default. |
Input Type
None
You cannot pipe input into this cmdlet.
Return Values
Citrix.Fma.Sdk.Utilities.Service.ServiceStatusInfo
The Get-ProvServiceStatus command returns an object containing the status of the MachineCreation Service together with extra diagnostics information.
OK
The MachineCreation Service is running and is connected to a database containing a valid schema.
DBUnconfigured
The MachineCreation Service does not have a database connection configured.
DBRejectedConnection
The database rejected the logon attempt from the MachineCreation Service. This may be because the service attempted to log on with invalid credentials or because a database has not been installed in the specified location.
InvalidDBConfigured
The expected stored procedures are missing from the database. This may be because the MachineCreation Service schema has not been added to the database.
DBNotFound
The specified database could not be located with the configured connection string.
DBMissingOptionalFeature
The MachineCreation is connected to a database that is valid, but it does not have the full functionality required for optimal performance. Upgrading the database is advisable.
DBMissingMandatoryFeature
The MachineCreation is connected to a database that is valid, but it does not have the full functionality required so the MachineCreation cannot function. Upgrading the database is required.
DBNewerVersionThanService
The version of the MachineCreation Service currently in use is incompatible with the version of the MachineCreation Service schema on the database. Upgrade the MachineCreation Service to a more recent version.
DBOlderVersionThanService
The version of the MachineCreation Service schema on the database is incompatible with the version of the MachineCreation Service currently in use. Upgrade the database schema to a more recent version.
DBVersionChangeInProgress
A database schema upgrade is currently in progress.
PendingFailure
Connectivity between the MachineCreation Service and the database has been lost. This may be a transitory network error, but may indicate a loss of connectivity that requires administrator intervention.
Failed
Connectivity between the MachineCreation and the database has been lost for an extended period of time, or has failed due to a configuration problem. The MachineCreation service cannot operate while its connection to the database is unavailable.
Unknown
(0) The service status cannot be determined.## Notes
If the command fails, the following errors can be returned.
Error Codes
-----------
DatabaseError
An error occurred in the service while attempting a database operation.
DatabaseNotConfigured
The operation could not be completed because the database for the service is not configured.
DataStoreException
An error occurred in the service while attempting a database operation - communication with the database failed for various reasons.
PermissionDenied
You do not have permission to execute this command.
AuthorizationError
There was a problem communicating with the Citrix Delegated Administration Service.
CommunicationError
There was a problem communicating with the remote service.
ExceptionThrown
An unexpected error occurred. For more details, see the Windows event logs on the controller or the XenDesktop logs.
Examples
EXAMPLE 1
C:\PS>Get-ProvServiceStatus DBUnconfigured
Description
-----------
Get the current status of the MachineCreation Service.